Terminal Crimp Process Verification Report
Report No.:  
Project Name:   Manufacturer:  
Project Type:   Preparing Location:  
Requested By:   Request Date:  
Prepared By:   Completion Date:  
Insulation Crimp Cross Section
2C_16_33213.bmp
 
Observations
Evaluation based on IPC A-620 sec. 5.1.1  
Based on observations, classify this insulation crimp cross section as acceptable, process issue, or design issue.
Check points Classification
Insulation crimp wings contact at least 180 degrees of the insulation surface. Acceptable
End of each wing contacts the wire insulation. (Overlapping crimp has end of one wing in contact with insulation.) Acceptable
None of the wings penetrate the insulation. (This is not allowed by Whirlpool) Acceptable
Crimp is symmetrical. Acceptable
No insulation extruded between the wing gaps.  Wing gap is not greater than 45 degrees. Acceptable
Additional Comments:  
   
 
Category Measurement Specification** Meets Criteria?
Height* 3.11 NO SPECIFICATION Yes
Width* 3.496 NO SPECIFICATION Yes
*Measurements are from a 1 piece sample set              
** Reference Only
Measurement Criteria
1.  C-4 - 7.4.4
2.  IPC A-620
3.  SAE/USCAR-21